Chemicals
Our chemicals
Boilers
Many heat applications use water as heat medium.In most cases, these systems should be treated to avoid corrosion and deposits to minimize heat loss, repairs and production losses.
Aquatreat provides for the treatment of above systems high-tech, environmentally friendly products that are cost saving by their very efficient operation.
Here you will find more information about our main products for the treatment of boiler water for low, middle and high pressure steam boilers.
LeveL-650 B
- LeveL-650 B is a one-shot product which can be dosed by a single dosing pump, a total treatment of feed tank, boiler water and steam/condensate lines is realized.
- Thanks to years of intensive R&D/optimization production processes, we managed to bring the most concentrated product on the market for this total treatment.
- All existing chemical components meet FDA § 173.310. (allowed chemical components if the steam is formed in direct contact with food).
- In the steam phase ammoniumcarbonate or ammoniumbicarbonate are formed . Both chemical components are used as a food additive (European Regulation No 1333/2008)!
- All chemical components are REACH-registered for all relevant identified uses
- Thanks to the use of LeveL-650 B all problems (oxygen/General corrosion, inorganic/organic deposits, making wet steam, acid corrosion, condensate lines …) are reduced to a minimum.! Even silicate deposits can be removed by (long-term, but safe) use of AQUATREAT 650! Thanks to an optimization of the blowdown quantity, it is possible to achieve the lowest possible energy, water and chemicals invoice .
- By utilizing LeveL-650 B your installation will be conform with the European standards:
- Fire tube boilers: EN_12953-10: 2003
- Water tube boilers: EN_12952-12: 2003
LeveL-690 B
- LeveL-690 B is a liquid product, suitable for the treatment of boiler
water to prevent corrosion and deposits in the boiler. - LeveL-690 B protects the steam and condensate lines against corrosion. Also, the product will slowly remove existing deposits.
- LeveL-690 B is phosphate free
LeveL-695 B
- LeveL-695 B is a liquid product, suitable for the treatment of boiler
water to prevent corrosion and deposits in the boiler. - LeveL-695 B protects the steam and condensate lines against corrosion. Also, the product will slowly remove existing deposits.
- LeveL-695 Bis extremely suitable to use at feed water with low buffering capacity as RO-, demineralized water or feed water with a large proportion return condensate.
- Application: Boilers with return-condensate, RO or demi-water as feed water.
Cooling water treatment
Water is a commonly used cooling agent in the industry. In each cooling equipment the condenser, heat exchanger and the cooling tower packing have to keep working optimal to accomplish a maximum efficiency. This can only be accomplished with a sufficient water treatment to inhibit the corrosion that can occur and to prevent the formation of organic and inorganic scale/deposits. Good maintenance and treatment is also necessary to control growth of the Legionella bacteria.
LeveL-21 BV has a wide variety of high technological products to propose an optimal treatment for each system. We have products to treat open recirculating cooling systems as well as closed systems and once through cooling systems to prevent the mentioned problems.
LeveL-202 C
- Excellent dispersion
- Corrosion inhibition
- Strong bio-dispersing
- Prevents and removes inorganic scale
- Cleaning properties
- No acid dosing required
- Active against biofouling, synergy with biocides
Treatment of closed circuits
LeveL-128 C
LeveL-128 C is a strong concentrated liquid product that can be used in soft and hard drinking water to prevent corrosion and scaling.
Application: direct use in drinking water, food graded
LeveL-130 C
Level-130 C is a strong concentrated liquid, corrosion inhibitor for protection of all metals in closed recirculating water systems.
LeveL-130 C is a nitrite-borate-silicate based corrosion inhibitor, an organic cupper corrosion and dispersing agents. There are neither heavy metals nor phosphates
Application: hot water-, cold water-, ice water-, glycol water- and salt water systems.
LeveL-136 C
Level-136 C is a strong concentrated liquid corrosion inhibitor for protection of all metals in closed recirculating water systems. LeveL-136 C is a molybdate/phosphate based inhibitor. There are also organic cupper corrosion inhibitors and strong dispersing agents present in LeveL-136 C
Application: hot water-, cold water-, ice water-, glycol water systems.
Biocides
LeveL-411 BC
LeveL-411 BC is a liquid, broad-spectrum microbiocide, especially developed for bacteriological control of industrial cooling water systems.
LeveL-411 BC contains quaternary ammonium salts, complex amines, dispersants and wetting agents.
LeveL-411 BC acts, due to its particular composition, as a bactericide and algicide at a pH range between 6 and 9 and stays effective in water with high hardness content.
LeveL-414 BC
LeveL-414 BC is a liquid, broad-spectrum microbiocide, especially developed for bacteriological control of industrial cooling water systems.
LeveL-414 BC is based on a mixture of isothiazolines.
LeveL-414 BC is active at a pH range between 4 and 12.
LeveL-414 BC is a non-oxidizing biocide and non-corrosive to materials
Anti-scalent & anti-fouling agents for RO
LeveL-522 AS
- Most cost effective and high concentrated antiscalant
- Typical dosing 1-3 mg/l on the feed water
- Most suitable for SWRO, 0,5-1,5 mg/l on the feed water
- High thresshold for scaling
- Phosphonate based and polymer technology
- NSF certification for production of drinking water Best way to verify the concentration by measurements
LeveL-520 AS
- More reliable dosing with smaller systems due to limitations of dosing pumps
- Typical dosing 2-10 mg/l on the feed water
- High thresshold for scaling
- Phosphonate based and polymer technology
- NOT NSF certificatied (LeveL-559 AS as alternative)
LeveL-535 AS
- The 2nd three = phoshpate free
- Typical dosing 2-10 mg/l on the feed water
- High thresshold for scaling
- Only based on polymer technology, no phosphate/phosphonate
- NSF certification for production of drinking water
LeveL-539 AS & LeveL-559 AS
- Extra benificial for pure silica, biofilm and iron
- Neutralization of slam amounts of free chlorine
- Typical dosing 2-10 mg/l on the feed water
- High thresshold for scaling
- LeveL-559 AS Phosphonate based and polymer technology
- LeveL-539 AS only based on polymer technology, no phosphate/phosphonate
- NSF certification for production of drinking water
LeveL-553 AS
- When the system is small, this AS has it all
- Best option for systems below 5 m³/hour
- Typical dosing 5-50 mg/l on the feed water
- High thresshold for scaling
- Phosphonate based and polymer technology
- NSF certification for production of drinking water
All are products are quality controlled with ISO 9001 and NSF standards to ensure the products meet your demands.
We advise not to dilute any of our LeveL products to avoid possible contaminations and biofilm formation
Antifoams
LeveL-610 AF
LeveL-610 AF is a good-grade antifoaming agent, with EEC number: E471 and FDA number: CFR 182.4505.
LeveL-610 AF has been developed to prevent foaming during the production of jam, glucose syrups, concentrated fruit juices, etc.
LeveL-610 AF contains saturated and non-saturated mono- and diglycerides.
Level-610 AF can be dispersed in viscous liquids and can also be used at higher temperatures. The typical dosage ranges between 50-100 mg/kg.
LeveL-611 AF
LeveL-611 AF is a copolymer of ethylene oxide and propylene oxide with antifoaming properties.
LeveL-611 AF can be used as a non-foaming wetting agent in dishwashing, bottle washing, protein and starch production, metal cleaning, boiler water and anti-freeze formulations.
LeveL-611 AF becomes more efficient as temperature increases (optimal temperatures from 50°C).
LeveL-611 AF can be used alone or in combination with other surfactants. AQUATREAT 611 can be dispersed in water or dissolved in alcohol before use.
Cleaning agents for RO
LeveL-841 CA
- LeveL 841 CA is a high concentrated liquid that can be used to remove hard-scale quickly.
- LeveL 841 CA is composed of food-graded organic acids.
- LeveL 841 CA is designed to clean membranes (ultra filtration, reverse osmosis…), heatexchangers, boilers, piping and vessels from scales composed of hardness and corrosion products.
- LeveL 841 CA can be used in the presence of all metals.
- LeveL 841 CA is less hazardous compared to passivated acids as there are sulphuric and hydrochloric acid.
- LeveL 841 CA can be used in the food industry (E 330)
LeveL-858 CA
- LeveL 858 CA is a strong alkaline liquid that can be used to efficiently remove inorganic and organic deposits in only one cleaning-step!
- LeveL 858 CA is used to clean membranes of reverse osmosis, ultrafiltration, nanofiltration and microfiltration.
- LeveL 858 CA is also used to clean heat-exchangers, piping and vessels from hardness scales, rust and organic fouling (biofilm).
- LeveL 858 CA can be used in the presence of all metals except galavanised steel, aluminium, zinc or one of their alloys.
- LeveL 858 CA is 100% food graded!
LeveL-801 CA
- LeveL 801 CA is a liquid that can be used to remove hard-scale quickly.
- LeveL 801 CAL is composed of organic acids, dispersants, wetting-agents and corrosion-inhibitors.
- LeveL 801 CA is designed to clean heat-exchangers, boilers, piping and vessels from scales composed of hardness and corrosion products.
- LeveL 801 CA can be used in the presence of all metals currently used, except zinc, aluminium and its alloys (in this case LeveL 810 CA should be used).
- LeveL 801 CA is less hazardous compared to passivated acids as there are sulphuric and hydrochloric acid.
LeveL-810 C
- LeveL 810 CA is a liquid that can be used to remove hard-scale quickly.
- LeveL 810 CA is composed of organic acids, dispersants, wetting-agents and corrosion-inhibitors.
- LeveL 810 CA is designed to clean heat-exchangers, boilers, piping and vessels from scales composed of hardness and corrosion products.
- LeveL 810 CA can be used in the presence of all metals, especially zinc, aluminium and its alloys.
- LeveL 810 CA is less hazardous compared to passivated acids as there are sulphuric and hydrochloric acid.
Pottable water
- LeveL-128 PW is a highly concentrated, liquid corrosion inhibitor based on polysilicates and polyphosphates giving an anodic and cathodic protection.
- LeveL-128 PW protects steel, copper, zinc, aluminium and their alloys against corrosion. This product also acts as a dispersant on iron oxide and hardness deposits.
- LeveL-128 PW is NSF/ANSI 60 certified and can be used in drinking water applications at a maximum concentration of 110 mg/l.
- LeveL-128 PW is dosed continuously at a concentration between 30 – 80 ppm.
- Control: determination of total phosphate (PO4) concentration.
- System pH should be maintained between 6,0 and 8,5 and temperatures up to 80°C.
- LeveL-128 PW contains 5,9% of total phosphate, expressed as PO4.
Polymers
In the purification of industrial and domestic waste water coagulation and flocculation are important steps. These steps are responsible to create a good flocculation of the macroscopic particles which increases the efficiency and rate of the sedimentation. For an optimal process the choice of the proper coagulant and flocculants is of great importance.
There is a wide variety in these products based on the type of charge (anionic or cationic), the charge density and the average molecule weight of the polymer. The efficiency of coagulant-flocculants is strongly influenced by the kind and composition of the waste water.
To test the efficiency of the coagulant-flocculants a jar test is commonly used. With the commonly used “jar test” it is possible to determine the right product and the optimal dose.
- LeveL-912 P
LeveL-912 P is a high molecular weight cationic polymer based on poly-imines. This product is used as an emulsionbreaker, flocculation aid, flottation aid and filtration aid.
- LeveL-946 P
LeveL-946 P is an anionic flocculant composed of polyacrylamide used to treat wastewater and handling sludge of waste-water treatments.